STC-4SS-38130 Langevin Transducer for Cleaner
Piezoelectric Transducer
![]() |
OPTION A: Horn Surface With Threaded hole for mounting |
Data Sheet STC-4SS-38130 - Option A (Horn Surface w/ Threaded hole)
GENERAL APPLICATION
Ultrasonic Cleaning
SPECIFICATIONS
Tests environmental conditions: 23 ± 3 °C; 40 ~ 70% RH
| Parameter | Specification | Remarks | |
| Resonant Fequency | fr | 130 ± 1 kHz | HP-4194 Impedance Analyzer at 1Vrms |
| Resonance Resistance | Ro |
< 15 ohm |
HP-4194 Impedance Analyzer at 1Vrms |
| Static Capacitance | Cp | 4800pF ± 10% | LCR meter at 1kHz, 1Vrms |
| Mass | g | ||
| Max Diameter | D | 40 mm | |
| Length | L | 54.3mm | |
| Max Input Power | P | 60 W |
MOUNTING OPTIONS AND DIMENSIONS
- OPTION A: Threaded mounting hole in the horn surface for screw fixing
|
OPTION A
|
HOW TO ORDER
If you need a specific quote, please request so by sending us an e-mail through "Request for Quote" by refering to the following part number or by calling us at 814-861-5688 (8:30am to 5:30pm EST). You can also directly place an order by calling us with your credit card information or sending us a Purchase Order form.
Purchasing Options
Article |
PartNumber |
Price unit |
|
Bolt Clamped Langevin Ultrasonic Transducer - Option A: Horn with Threaded Hole |
STC-4SS-38130 Option A |
1-9: $80.00
10-24: $45.00
25-99: $30.00
|





Cleaning